Multi-Unit abutments from IPD for compatible implant systems, straight and angled, as well as Multi-unit AP and Custom Ti-Base at Multi-Unit level. The components are sorted by implant system and platform.
Multi-unit Abutment – Zimmer Screw Vent – Ø3.5 – 30° – GH 3.5
FA-MN-33/AP
Multi-unit Abutment – Straumann Bone Level – NC Ø3.3 – 30° – GH 4.5
DB-MN-34/AP
Multi-unit AP – Straumann Bone Level – NC Ø3.3 – 30° – GH 3.5
DB-MN-33/AP
Multi-unit Abutment – Straumann Bone Level – NC Ø3.3 – 17° – GH 3.5
DB-MN-13/AP
Multi-unit AP – Straumann Bone Level – NC Ø3.3 – 17° – GH 2.5
DB-MN-12/AP
Multi-unit AP – Astra Osseospeed™ – Aqua Ø3.5-Ø4.0 – 30° – GH 4.5
EA-MR-34/AP
Multi-unit AP – Astra Osseospeed™ – Aqua Ø3.5-Ø4.0 – 30° – GH 3.5
EA-MR-33/AP
Multi-unit AP – Astra Osseospeed™ – Aqua Ø3.5-Ø4.0 – 17° – GH 3.5
EA-MR-13/AP
Multi-unit AP – Astra Osseospeed™ – Aqua Ø3.5-Ø4.0 – 17° – GH 2.5
EA-MR-12/AP
Multi-unit AP – Nobel Biocare Active® / Replace® (Conical) – NP Ø3.5 – 30° – GH 3.5 – PH 4.5
AD-MN-34/AP
Multi-unit AP – Nobel Biocare Active® / Replace® (Conical) – NP Ø3.5 – 30° – GH 3.5
AD-MN-33/AP
Multi-unit AP – Nobel Biocare Active® / Replace® (Conical) – NP Ø3.5 – 17° – GH 3.5
AD-MN-13/AP
Multi-unit AP – Nobel Biocare Active® / Replace® (Conical) – NP Ø3.5 – 17° – GH 2.5
AD-MN-12/AP
Multi-unit AP – Straumann Bone Level – RC Ø4.1 – 30° – GH 4.5
DB-MR-34/AP
Multi-unit AP – Straumann Bone Level – RC Ø4.1 – 30° – GH 3.5
DB-MR-33/AP
Multi-unit Abutment – Straumann Bone Level – RC Ø4.1 – 17° – GH 3.5
DB-MR-13/AP
Multi-unit Abutment – Straumann Bone Level – RC Ø4.1 – 17° – GH 2.5
DB-MR-12/AP
Multi-unit AP – Nobel Biocare Active® / Replace® (Conical) – RP Ø4.3 – 30° – GH 4.5
AD-MR-34/AP
What is a Multi-Unit abutment?
A Multi-Unit abutment is a transepithelial abutment that is screwed directly onto the implant. The top is a universal platform for IPD's Multi-Unit components (Multi-unit RP Ø4.8), and bridges or bars are screwed onto the abutment.
According to IPD, straight Multi-Unit abutments can be used for both single and multiple restorations. The angled ones are used for screw-retained bridges and removable dentures on several implants.
The workflow
The abutment is placed with a carrier, the seating is checked with an X-ray, and the abutment is tightened with the Multi-Unit screwdriver. Until the final prosthesis is ready, a temporary abutment or a healing abutment at Multi-Unit level is used. In the digital workflow, bridges and bars are produced with the aid of a scan body.
See also Custom Ti-Base and all IPD components.


























