Vitamin D in the clinic

Chairside vitamin D test and reader from botissCARE and VHC.

botissCARE · Vitamin D in the clinic

Know your patient's vitamin D level before you treat

With botissCARE or VHC you measure vitamin D chairside from a drop of capillary blood. The result is ready after about 15 minutes, while the patient is still in the clinic.

approx. 15 minfrom sample to result
98%correlation with LC-MS/MS, the laboratory gold standard
1 dropof capillary blood from the fingertip
Why vitamin D

Vitamin D as part of the treatment plan

Vitamin D helps the body absorb calcium and plays a role in bone metabolism and the immune system. These are the processes that need to work when an implant has to integrate, or when bone and soft tissue have to heal.

In the winter months, the skin produces little or no vitamin D in northern Europe. With a chairside test you can test and advise directly in the clinic.

botissCARE: test, analyse and prevent
What the clinic gets

Test and result in the same visit

All in one

Test, reader and consumables from one system, so you can test and advise directly in the clinic.

15 minutes

The result is ready while the patient is still in the clinic. No referral and no waiting for the laboratory.

Peace of mind

When you know the patient's vitamin D status, you can take it into account when planning implants and bone augmentation.

Dr. Miguel Stanley on vitamin DIn English · 2:23The video only loads from Vimeo when you press play.
In the expert's words

Dr. Miguel Stanley on vitamin D

Dentist Dr. Miguel Stanley from Lisbon explains why he measures vitamin D in his patients and how it is part of his treatments.

“We are not just mechanics, we are doctors of the oral cavity.”
Dr. Miguel Stanley, dentist
Vitamin D test with botissCARE in the dental clinic
What do the studies say?

Low vitamin D and early implant failure

Two retrospective studies from the same clinic followed a total of 3,365 implants. The share of patients with early implant failure rose as the vitamin D level fell:

The difference was not statistically significant, and the authors call for larger prospective studies. Still, the trend is a good reason to know the number before you plan surgery.

Sources: Mangano F et al. Mediators Inflamm. 2016;2016:5319718 · Mangano F et al. J Dent Res Dent Clin Dent Prospects. 2018;12(3):174–182

How the test works

From finger prick to result in about 15 minutes

  1. Prick the finger

    Clean the finger and collect the blood with the UniSampler collector.

  2. Mix with buffer

    Transfer the blood to the collection tube with buffer solution and mix.

  3. Three drops on the cassette

    Apply exactly three drops to the Rapi-D test cassette.

  4. Read

    After 15 minutes, insert the cassette into the Cube Reader and read the result in ng/ml.

See the handling step by stepIn English · 2:17The video only loads from Vimeo when you press play.

How to read the result

The Cube Reader shows total 25-OH vitamin D in ng/ml. botiss classifies the result like this:

Deficient< 10 ng/ml
Insufficient10–30 ng/ml
Sufficient30–100 ng/ml

Many laboratories report in nmol/l. The value in nmol/l is 2.5 times the value in ng/ml, so 30 ng/ml equals 75 nmol/l.

The test is a screening. If you find a deficiency, advise the patient to talk to their own doctor, especially before major surgery.

Another system

Vitamin D test from VHC

VHC is a separate system with its own reader and test cards. The reader measures optically and shows the vitamin D value on its own display after about 15 minutes.

  • Only 10 µl of capillary blood from the fingertip
  • Result after about 15 minutes as a number and level 1–6
  • Measuring range 3–100 ng/ml (7.5–250 nmol/l)
  • Externally quality-controlled through the international DEQAS programme
Questions and answers

What clinics ask

Why test vitamin D in the dental clinic?

Vitamin D plays a role in bone metabolism and the immune system, and the result can be part of planning before implants, bone augmentation and periodontal treatment. The test takes about 15 minutes and can be done during the appointment.

When does it make sense to test?

Typically when planning implant surgery or bone augmentation, in patients with periodontitis, and again after a period of supplementation to see whether the level has risen.

How accurate is the test?

botiss states a correlation of 98% with LC-MS/MS, the laboratory gold standard. The test is a screening, and an abnormal result can be confirmed by the patient's doctor.

What is the difference between ng/ml and nmol/l?

They are two units for the same thing. The Cube Reader reports in ng/ml, while many laboratories report in nmol/l. Multiply the value in ng/ml by 2.5 to get nmol/l.

What is in the starter kit?

1 Cube Reader, 50 Rapi-D tests (2 × 25), 200 lancets, 2 product leaflets and a quick guide. Each Rapi-D pack contains 25 tests, collection tubes with buffer, blood collectors and an RFID card that calibrates the reader to the test batch.

The full range

You will find all tests, readers and consumables for vitamin D measurement in the Diagnostics collection.

Images and videos: botiss biomaterials GmbH.