TruNatomy and SlimShaper are low-taper rotary file systems made of heat-treated nickel-titanium (NiTi), designed for conservative canal preparation. In three laboratory studies using 3D-printed teeth, the two systems shaped and cleaned the canal without a significant difference. In the only fatigue test of both, SlimShaper withstood fewer cycles than TruNatomy, but the significance was not reported. Clinical comparisons are lacking.
What characterizes TruNatomy and SlimShaper as minimally invasive file systems?
Minimally invasive endodontics is about cleaning and shaping the canal while preserving as much dentin as possible, especially around the canal entrance. Low-taper files remove less dentin, but also leave a narrower canal. Both systems belong to the rotary files. A closer look at NiTi files, file breakage, and heat treatment is in the basic knowledge article NiTi root canal files: systems, motion, and file sequences.
Puredent stocks SlimShaper and SlimShaper PRO, but not TruNatomy. The article is based on the manufacturers' own information and on the studies where TruNatomy and SlimShaper are tested in the same trial.
TruNatomy
TruNatomy from Dentsply Sirona consists of an Orifice Modifier (20/.08), a Glider (17/.02v), and the shaping files Small (20/.04v), Prime (26/.04v), and Medium (36/.03v). The treatment begins with Prime, and Small or Medium is used if Prime does not advance or is loose. All files are run at 500 revolutions per minute (rpm) and 1.5 Ncm.9 According to Dentsply Sirona, the files are made of heat-treated NiTi with a maximum diameter of 0.8 mm.9
SlimShaper
SlimShaper from Zarc Endo consists of three files, ZS1, ZS2, and ZS3. According to Zarc, ZS1 has a tip size of 15, ZS2 size 20, and ZS3 size 25, and the system has three heat treatments: Gold, Pink, and Blue.7 The files are run at 500 rpm and 3 Ncm, and the instructions for use allow 300 to 500 rpm and describe the settings as guidelines.7 According to Zarc, SlimShaper PRO has the same file names and two heat treatments in each file.8
TruNatomy and SlimShaper side by side
The information is from the manufacturers themselves. TruNatomy's shaping files are available in 21, 25, and 31 mm.9 At Puredent, SlimShaper and SlimShaper PRO are available in 21, 25, and 31 mm.
TruNatomy
- Brand
- Dentsply Sirona
- Files
- Orifice Modifier (20/.08), Glider (17/.02v), Small (20/.04v), Prime (26/.04v), and Medium (36/.03v)
- Starting file
- Prime
- Motor
- 500 rpm and 1.5 Ncm
- Glide path
- K-file size 10, then TruNatomy Glider
- Use
- Single use
SlimShaper
- Brand
- Zarc Endo
- Files
- ZS1 (15), ZS2 (20), and ZS3 (25), variable taper
- Heat treatment
- Gold, Pink, and Blue in the system; SlimShaper PRO has two in each file
- Motor
- 500 rpm and 3 Ncm, 300 to 500 rpm allowed (guideline)
- Glide path
- Hand files at least size 15, or a mechanical glide path file after a hand file size 10
- Use
- Single use
What do the studies show when TruNatomy and SlimShaper are tested against each other?
We have found four laboratory studies where TruNatomy and SlimShaper are tested in the same trial. Three are about shaping and cleaning in 3D-printed teeth, and one about fatigue. The three shaping studies found no significant difference between the systems, and in the fatigue test, TruNatomy withstood the most cycles, without the significance being reported:
| Investigated | SlimShaper | TruNatomy | Difference |
|---|---|---|---|
| Untreated canal wall | 32.0 % | 32.1 % | Not significant1 |
| Removed resin | 12.1 % | 11.9 % | Not significant1 |
| Remaining gel | 2.50 % | 4.20 % | Not significant3 |
| Remaining distal wall | 0.60 mm | 0.56 mm | Not significant2 |
| Cycles before breakage | 1,205.7 | 1,567 | Significance not reported4 |
| Healing and tooth survival | No comparative studies found | ||
The shaping and cleaning studies are done in printed copies of teeth, and in two of them SlimShaper was followed by an ApicalShaper. The sections below review each study.
How the studies should be read. All four comparative studies are laboratory studies in printed teeth and steel canals, and in three of them the authors have ties to Zarc. They say something about shaping and mechanics, not about healing or tooth survival. We have not found studies where TruNatomy and SlimShaper are compared in extracted teeth, at body temperature, or in the clinic.
Shaping and cleaning in printed teeth
In three laboratory studies in 3D-printed teeth, there were no significant differences between TruNatomy and SlimShaper in untreated canal wall, removed resin, remaining gel (simulated pulp tissue), or remaining wall thickness.1, 2, 3
Ramírez-Muñoz et al. measured in Materials in 2024 mesial canals in 3D-printed copies of mandibular molars with micro-computed tomography (micro-CT), 11 copies in each of six groups. SlimShaper was completed with an ApicalShaper (30/.03) and TruNatomy with Medium (36/.03), and the difference in removed resin was not significant (12.1 vs. 11.9 %). A group with TruNatomy and ApicalShaper, which ended at the same size as SlimShaper, was also not significantly different. Only BlueShaper PRO with ApicalShaper gave a significantly greater volume increase.1
In the study by Maqueda et al. in Dentistry Journal in 2026, 13 printed copies of a mesial root per group were filled with a gel and prepared with ProTaper Gold, TruNatomy, or SlimShaper. With ProTaper Gold, there was 0.15 % gel remaining, and that difference was also not significant. In the middle third, there was 1.5 % remaining with TruNatomy and 7.2 % with SlimShaper, also not significantly different. The study's calculations of stresses and the irrigation fluid's flow were based on one model per system and cannot show that one system is better.3
Ensinas and de la Casa prepared in Acta Odontológica Latinoamericana in 2025 the second mesiobuccal canal in 50 printed copies of a maxillary molar with four systems, 10 in each group, and measured the distal wall with cone beam-CT. The wall thickness is an average over the three thirds, and the canals were prepared to different apical sizes, 30 with SlimShaper and ApicalShaper and 36 with TruNatomy.2
Clinical perspective. In three studies in 3D-printed teeth, SlimShaper shaped and cleaned the canal without a significant difference from TruNatomy. SlimShaper can therefore be considered when a conservative preparation with low taper is the goal, but the studies do not show an advantage over TruNatomy. In two of the studies, SlimShaper was followed by ApicalShaper to size 30, all three used printed copies and not extracted teeth, and in two of them the authors have ties to Zarc. Healing is not investigated.1, 2, 3
Fatigue in 20 file systems
SlimShaper withstood fewer cycles before breakage than TruNatomy, on average 1,205.7 versus 1,567, in the only fatigue test we have found of both systems. The article does not report whether the difference was significant. Aranguren et al. tested in Materials in 2024 20 files from each of 20 systems in a steel canal with 60° curvature at room temperature, and both systems ran at 500 rpm. SlimShaper ran at 4 Ncm, not the 3 Ncm specified in the instructions for use. The article's table lists times that do not match the cycles for SlimShaper, so we only report the cycles.4, 7
Clinical perspective. In the only fatigue test of both systems, SlimShaper withstood fewer cycles than TruNatomy, and the significance is not reported. The study therefore does not speak for SlimShaper if fatigue resistance weighs heavily in the choice. The test was done at room temperature in a steel canal, SlimShaper ran at 4 Ncm instead of the 3 Ncm in the instructions for use, and three of the authors are opinion leaders for Zarc.4, 7
SlimShaper or SlimShaper PRO: what is the difference?
The standard SlimShaper lasted longer than SlimShaper PRO in ZS2 and ZS3, and the PRO version did not result in more apical transportation. This is shown by the two studies that have compared the versions. SlimShaper PRO has the same files and geometry, but according to Zarc two heat treatments in each file (DualWire).5, 6, 8 The studies against TruNatomy are done with the standard SlimShaper.
- Fatigue. ZS2 and ZS3 from the standard SlimShaper lasted significantly longer than the PRO versions, 59.5 versus 31.0 seconds and 67.0 versus 39.7 seconds, while ZS1 was not significantly different. This was found by Scolaro et al. in Dentistry Journal in 2026, who tested six files of each size in a canal with 45° curvature. Contrary to the authors' expectation, the heat analysis showed identical transformation temperatures in the tip and middle of the PRO files.5
- Apical transportation. The apical transportation was 0.084 mm with SlimShaper and 0.086 mm with SlimShaper PRO, without a significant difference, in a study by Puleio et al. in International Journal of Dentistry in 2026 with 22 curved resin blocks per group.6
Clinical perspective. If fatigue resistance weighs heavily, the studies speak for the standard SlimShaper. The authors behind the fatigue test point to SlimShaper PRO where more cutting ability is needed, but the cutting ability was not measured. SlimShaper PRO is not compared with TruNatomy.5, 6
What should you consider when choosing a minimally invasive file system?
None of the studies compare the systems clinically, and a lack of significant difference is not the same as the systems being equal. The studies point to four conditions that can be part of the choice:
- Shaping and cleaning. In three studies in printed teeth, TruNatomy and SlimShaper were not significantly different, so the studies do not give an advantage to either of them.1, 2, 3
- Fatigue. TruNatomy withstood more cycles than SlimShaper in the only study that has tested both, but the significance is not reported.4 The standard SlimShaper lasted longer than SlimShaper PRO in ZS2 and ZS3.5
- Apical size and sequence. SlimShaper ends at size 25 (ZS3). TruNatomy ends at Prime (26) or Medium (36).7, 9 In two of the studies, SlimShaper was followed by an ApicalShaper to reach size 30, so it can be considered when the preparation needs to end larger apically.1, 2
- SlimShaper or PRO. The results against TruNatomy cannot be directly transferred to SlimShaper PRO, which according to Zarc has a different heat treatment.8
- Motor and obturation. TruNatomy is run at 1.5 Ncm and SlimShaper at 3 Ncm, both at 500 rpm.7, 9 Dentsply Sirona has TruNatomy Conform Fit gutta-percha and paper points that according to the manufacturer fit the files, and Zarc has gutta-percha in the SlimShaper sizes ZS1 to ZS3.9, 10
SlimShaper at Puredent
If you are considering SlimShaper for conservative preparation, here are the products from Zarc Endo you have encountered in the article: SlimShaper and SlimShaper PRO, ApicalShaper, when the canal needs to end larger apically, and gutta-percha in the SlimShaper sizes. The studies against TruNatomy are done with the standard SlimShaper. The descriptions on the cards are the manufacturer's own.
-
SlimShaper
Three rotary files, ZS1 to ZS3, with three heat treatments in the system.
See SlimShaper → -
SlimShaper PRO
The SlimShaper files with according to Zarc two heat treatments in each file (DualWire).
See SlimShaper PRO → -
-
SlimShaper gutta-percha
Gutta-percha in the SlimShaper sizes ZS1 to ZS3.
See SlimShaper gutta-percha →
Frequently Asked Questions
What is the difference between TruNatomy and SlimShaper?
Both are rotary NiTi file systems with low taper. TruNatomy from Dentsply Sirona has an Orifice Modifier, a Glider, and shaping files, where Prime (26/.04v) is the starting file, and the manufacturer states a maximum diameter of 0.8 mm.9 SlimShaper from Zarc has three files, ZS1, ZS2, and ZS3, and three heat treatments in the system.7 TruNatomy is run at 1.5 Ncm and SlimShaper at 3 Ncm, both at 500 revolutions per minute.7, 9
Does the SlimShaper canal shape differently than TruNatomy?
Which file withstands more fatigue, TruNatomy or SlimShaper?
In the only study that has tested both, TruNatomy withstood an average of 1,567 cycles and SlimShaper 1,205.7 before fracture in a steel canal with 60° curvature. The study does not report whether the difference was significant, and three of the authors are opinion leaders for Zarc.4
What is the difference between SlimShaper and SlimShaper PRO?
According to Zarc, SlimShaper PRO has two heat treatments in each file (DualWire).8 In a laboratory study with no declared conflicts of interest, ZS2 and ZS3 from the standard SlimShaper lasted significantly longer in a fatigue test than the PRO versions, while ZS1 was not significantly different.5 In another study, there was no significant difference in apical transportation.6
Do TruNatomy and SlimShaper require a glide path?
Yes. According to the instructions for use, TruNatomy should only be used where there is a confirmed and reproducible glide path, created with a size 10 K-file and then TruNatomy Glider.9 For SlimShaper, Zarc requires a reproducible glide path with hand files of at least size 15 or a mechanical glide path file after a size 10 hand file.7
Interests
We disclose the authors' and Puredent's interests so you can assess the sources yourself.
- Puredent distributes one of the two file systems in the comparison and its PRO version, but not the other. Puredent also distributes the apical files from source 1 and 2 and a third file system from source 1.
- Source 1 (Ramírez-Muñoz et al.): The authors declare no conflicts of interest, but three of them, José Aranguren, Alejandro R. Pérez, and Ana Ramírez-Muñoz, declare themselves opinion leaders for Zarc in source 4 in the same year.1, 4
- Source 3 (Maqueda et al.): Aranguren and Pérez are opinion leaders for Zarc, and César de Gregorio and Simone Grandini for Dentsply Sirona.3
- Source 4 (Aranguren et al.): Aranguren, Pérez, and Ramírez-Muñoz are opinion leaders for Zarc.4
- Source 6 (Puleio et al.): The authors declare no conflicts of interest, but thank Zarc4Endo for support, and Aranguren is a co-author.6
- Source 2 and 5 (Ensinas and de la Casa; Scolaro et al.): The authors declare no conflicts of interest.2, 5
TruNatomy is a trademark belonging to Dentsply Sirona, and SlimShaper is a registered trademark belonging to Zarc4Endo. Other product names belong to their respective owners.
Sources
- Ramírez-Muñoz A, Escribano-Capdevila M, Navarrete N, Vieira GCS, Salamanca-Ramos M, Ortolani-Seltenerich PS, Aranguren J, Pérez AR. Comparative Micro-CT Analysis of Minimally Invasive Endodontic Systems Using 3D-Printed Replicas and Natural Teeth. Materials. 2024;17(21):5279. DOI (freely available)
- Ensinas P, de la Casa ML. Effect of mechanized instrumentation on distal wall thickness of the second mesiobuccal canal. Acta Odontológica Latinoamericana. 2025;38(2):170-178. DOI (freely available)
- Maqueda CV, Navarrete N, Ramírez-Muñoz A, Martín-Díaz A, de Gregorio C, Aranguren J, Malvicini G, Grandini S, Vieira GCS, Pérez AR. Impact of Taper Design on Cleaning Efficacy, Stress Generation, and Irrigant Performance: A Combined Experimental, Finite Element Analysis, and Computational Fluid Dynamics Assessment. Dentistry Journal. 2026;14(2):108. DOI (freely available)
- Aranguren J, Oliveros-Porras F, Ramírez-Muñoz A, Pérez I, Salamanca-Ramos M, Aazzouzi-Raiss K, Pérez AR. Comparative Analysis of NiTi Instruments with Different Alloy Treatments. Materials. 2024;17(19):4817. DOI (freely available)
- Scolaro C, Puleio F, Sili A, Visco A. Cyclic Fatigue Resistance and Phase Transformation Behavior of SlimShaper and SlimShaper PRO NiTi Instruments: A Mechanical and Thermal Analysis. Dentistry Journal. 2026;14(1):22. DOI (freely available)
- Puleio F, Pirri R, Aranguren J, Tosco V. In Vitro Evaluation of Apical Transportation Induced by Single- and Dual-Thermally Treated NiTi Instruments. International Journal of Dentistry. 2026;2026:6168069. DOI (freely available)
- Zarc4Endo. SlimShaper: instructions for use IFU-0175 rev. 03 and tip card (archived 24.05.2024). Instructions for use · Tip card · Product page
- Zarc4Endo. SlimShaper PRO: instructions for use IFU-0186 rev. 02 and product page. Instructions for use · Product page
- Dentsply Sirona. TruNatomy: instructions for use (US, rev. 00, 2018) and product pages. Instructions for use · Product page · Files
- Zarc4Endo. Gutta-percha: instructions for use. Instructions for use




Share: