Resorbable vs. non-resorbable membrane in bone augmentation

By Puredent Team Published October 14, 202612 min read
Short answer

In bone augmentation with guided bone regeneration (GBR), a meta-analysis of randomized trials found no statistically significant difference in bone formation between resorbable collagen membranes and non-resorbable expanded polytetrafluoroethylene (ePTFE) membranes. The difference lies in their properties: The non-resorbable membrane must be removed again, and with titanium reinforcement, it maintains space. The resorbable membrane degrades on its own but can collapse.

What is the difference between a resorbable and a non-resorbable membrane?

In GBR, a barrier membrane is placed over the bone defect, usually over a bone substitute material, to keep soft tissue out. The principle and the different membrane types are covered in the guide to guided bone regeneration. Here we compare the two main groups.

Non-resorbable membranes do not degrade in the body. The most studied are made of PTFE, either expanded (ePTFE) or high-density PTFE (dPTFE), with or without titanium reinforcement, as well as titanium mesh. It is the titanium reinforcement and mesh that maintain the shape. An unsupported PTFE membrane must be supported, e.g., with tenting screws.4 The membrane is removed at a new procedure, and if it becomes exposed, spontaneous healing is limited.1

Resorbable membranes degrade in the body and do not need to be removed. In the trials, they are most often made of collagen or synthetic polymers such as polyglactin 910 and polylactide/polyglycolide.1 The authors of a meta-analysis of 25 randomized trials, Cousiño et al., which we review below, describe it as a limitation that they can collapse, even when there is bone substitute material underneath.1

Resorbable and non-resorbable membrane point by point

Removal
Non-resorbable: at a new procedure. Resorbable: degrades in the body.1
Bone formation
No statistically significant difference between ePTFE and collagen in a meta-analysis of randomized trials.1
Shape stability
Less loss of buccal hard tissue after 6 months with titanium-reinforced ePTFE than with collagen in one small analysis from Zurich at dehiscences (Strauss et al., see below).2 Resorbable membranes can collapse.1
Complications
The authors of the meta-analysis describe multiple exposures and infections with non-resorbable membranes, but their pooled analysis showed no significant difference.1
Upon exposure
Non-resorbable: limited spontaneous healing, may require early removal.1, 3 Resorbable: can heal spontaneously after exposure according to Strauss et al.2

What do the trials comparing them show?

The broadest assessment is a meta-analysis published by Cousiño et al. from Barcelona in 2026 in Medicina Oral, Patología Oral y Cirugía Bucal. The pooled 25 randomized trials involving a total of 684 patients, published from 1995 to 2025, compared membranes with each other or with a control group.1 In the trials that could be pooled, they found:

  • Bone formation: no statistically significant difference between ePTFE and collagen membranes, with an average difference of -0.09 mm (95% confidence interval (CI) -0.41 to 0.22). The authors describe the heterogeneity between the trials as high (I² = 49%).1
  • Success rate: no statistically significant difference, with a relative risk (RR) of 1.00 (95% CI 0.95 to 1.06). The trials defined success differently.1
  • Complications: no statistically significant difference (RR 1.01, 95% CI 0.69 to 1.48).1

The authors nevertheless conclude that resorbable membranes have fewer complications, and that non-resorbable membranes are exposed and infected more often, but provide greater shape stability. This conclusion appears to be based on their review of the trials individually, not on the pooled analysis. Exposure was the most frequently reported complication and was described in at least 12 of the trials.1 The trials were of mixed quality: 8 of the 25 had a high risk of bias, most had a follow-up of around 12 months, and the most common defects were periodontal bone defects and furcations, followed by extraction alveoli and implant defects. The selection of studies was primarily performed by one person.1

The review also mentions a trial published after the search: Hindryckx et al. compared dPTFE with collagen in lateral bone augmentation in the anterior maxilla. The bone gain after 9 months was at the same level, but the dPTFE group had more infections (33%, P = 0.019).1

One of the included trials specifically looks at implants. Strauss et al. from Zurich published a secondary analysis of a randomized trial that began in 2010 in Clinical Oral Investigations. 27 patients received an implant in a single tooth gap from the second premolar to the second premolar and simultaneously GBR at a buccal dehiscence with bovine bone substitute material under either a collagen membrane or a titanium-reinforced ePTFE membrane.2

  • 0.8 mm average loss of buccal hard tissue over 6 months with collagen membrane (n = 12)
  • 0.1 mm average loss with titanium-reinforced ePTFE membrane (n = 13), not significant

The loss was significantly greater with collagen than with ePTFE. In the 7 patients in each group where the soft tissue could also be measured, there was a non-significant trend toward the mucosa being approximately 0.6 mm thicker in the collagen group, and the contour lost only 0.2 mm and 0.1 mm. The authors assess that the thicker soft tissue can partly explain that the contour was stable.2

The analysis has significant limitations. The parent study was calculated for 34 patients, but only 27 were included, and the trial was not registered. The vertical defect was larger at the start in the collagen group (4.0 mm) than in the ePTFE group (2.3 mm). There were four dehiscences in the collagen group and two in the ePTFE group. The scan after 6 months was taken in the ePTFE group after the membrane had been removed, and in the collagen group before the flap was lifted. The measurements are of hard tissue including bone substitute material, and the authors themselves mention that thin bone layers are difficult to see on the scan.2 Cousiño et al. also report a five-year follow-up from the Zurich group (Naenni et al.), where the bone changes were small in both groups, slightly less with ePTFE.1

What happens if the membrane becomes exposed?

Poli et al. reviewed studies of exposed non-resorbable membranes in a scoping review in The International Journal of Oral & Maxillofacial Implants: 11 on PTFE membranes and 24 on titanium mesh. Only studies that described the treatment of an exposure were included, so the review says something about the management, not how often exposure occurs. We have only had access to the abstract.3

  • Exposure was most often treated pharmacologically or mechanically.3
  • After treatment, 44.4% of the exposed PTFE membranes and 11.9% of the exposed titanium mesh were removed.3
  • The authors assess that chlorhexidine and careful plaque control can provide better conditions for healing, and that removal of the exposed part can be considered. A beneficial effect of systemic antibiotics on the exposure could not be demonstrated, but it should be considered if the bone substitute material becomes infected.3

Strauss et al. mention that resorbable membranes have the possibility of healing spontaneously after exposure, but also that exposure according to another meta-analysis can impair bone formation in both types.2

When do you choose a resorbable membrane for bone augmentation?

Cousiño et al. conclude that both types are effective, and that the choice should depend on the defect, the procedure, and the patient's medical history.1 The sources provide some guidelines:

  • Defined defects around an implant, e.g., a dehiscence, have been studied with both types. A resorbable membrane may be considered. The analysis from Zurich, however, suggests that the augmented hard tissue was more stable under a titanium-reinforced ePTFE membrane after 6 months.2 In the trial from Zurich, the membrane was removed at the re-procedure that was performed after 6 months.2
  • Vertical and large defects require that space is maintained. Cousiño et al. describe that a resorbable membrane here must have support, e.g., a titanium mesh, and that non-resorbable membranes and titanium mesh are especially relevant for large defects and ridges without bone walls.1
  • Management of exposure should be considered in advance when using a non-resorbable membrane, because an exposed membrane may end up having to be removed early.3

The choice of membrane, bone substitute material, and technique for the individual patient is the treating dentist's assessment.

What do studies of the membranes in our range show?

permamem (dPTFE). According to Palkovics et al., permamem is primarily intended for open healing with preservation of the alveolus, and the authors describe the dense structure as impermeable to bacteria.4 In BMC Oral Health, they described how the membrane performed outside the primary indication: in vertical bone augmentation in eight patients, with tenting screws to maintain space and a 1:1 mixture of autologous bone and cerabone.4

  • The membrane became exposed in four of the eight, between the fourth and sixth week. In the three larger exposures (class II), the membrane was removed between weeks 6 and 12, and the area was covered with a resorbable collagen membrane.4
  • After nine months, the vertical gain of hard tissue was on average 3.80 mm: 4.06 mm in the four where the membrane remained covered, and 3.55 mm in the four with exposure. The implants could be placed without further augmentation.4
  • Measured 1-3 mm below the top of the ridge, the width was less after nine months than at the start, e.g., 5.75 mm versus 6.93 mm 2 mm below the top.4

The authors assess that exposure had a less negative impact than previously reported for ePTFE. It is a comparison with other literature, not with a control group. The study is a case series of eight selected patients from a larger ongoing study, without statistical testing, and the authors call for larger comparative studies.4

Jason membrane (collagen from porcine pericardium). Lee et al. compared Jason with a cross-linked collagen membrane in a randomized trial in Materials, both placed over a preformed titanium mesh at dehiscences around single implants in the anterior maxilla. In the 28 patients who were evaluated, the horizontal gain of hard tissue after six months was 2.27 mm with Jason and 2.44 mm with the cross-linked membrane, without statistically significant difference. Two of the 30 enrolled patients, where the titanium mesh became exposed, were not included in the analysis.5 The trial shows a resorbable membrane used over a non-resorbable placeholder, not a comparison of the two main groups.

Membranes in Puredent's range

  • Package with permamem non-resorbable membrane made of high-density PTFE

    permamem

    Non-resorbable membrane made of dPTFE without reinforcement.

    See product →
  • Package with NeoGen non-resorbable PTFE membrane with titanium reinforcement

    NeoGen Ti-Reinforced

    Non-resorbable PTFE membrane with titanium reinforcement.

    See product →
  • Package with Jason resorbable collagen membrane made of pericardium

    Jason membrane

    Resorbable collagen membrane made of porcine pericardium.

    See product →
  • Package with collprotect resorbable collagen membrane

    collprotect membrane

    Resorbable collagen membrane made of porcine dermis.

    See product →
  • Package with NOVAMag resorbable membrane made of magnesium

    NOVAMag membrane

    Resorbable membrane made of magnesium.

    See product →
See all membranes See membranes and bone substitute materials

Frequently asked questions about membranes in bone augmentation

Does a non-resorbable membrane need to be removed again?

Yes. A membrane made of polytetrafluoroethylene (PTFE) or a titanium mesh does not degrade and is removed at a new procedure, typically six to eight months after placement, according to Cousiño et al.1. A resorbable membrane degrades in the body. In a trial with simultaneous implant placement, the membrane was removed at the re-procedure after 6 months2.

Does a non-resorbable membrane provide more bone than a resorbable one?

This cannot be concluded from the current evidence. A meta-analysis found no statistically significant difference in bone formation between ePTFE and collagen membranes, with an average difference of -0.09 mm1. However, a secondary analysis of a randomized trial at dehiscences around implants found less loss of buccal hard tissue after 6 months with a titanium-reinforced ePTFE membrane than with a collagen membrane2.

What should be done if a PTFE membrane becomes exposed?

A scoping review found that exposure was most often treated pharmacologically or mechanically. The authors assess that chlorhexidine and meticulous plaque control can provide better conditions for healing, and that removal of the exposed part can be considered. A beneficial effect of systemic antibiotics on the exposure itself could not be demonstrated3. The specific management is the clinician's assessment.

Can a resorbable membrane be used for vertical bone augmentation?

Cousiño et al. describe that a resorbable membrane for vertical augmentation requires additional support, e.g., a titanium mesh. In a study reported by the review, the vertical gain was 7.8 mm with titanium-reinforced PTFE and 7.4 mm with a collagen membrane over a titanium mesh1. This is one study, and the choice for the individual defect is the clinician's assessment.

Are non-resorbable membranes exposed more often?

The authors of a meta-analysis of randomized trials conclude that exposure and infection are more common with non-resorbable membranes. However, in the trials that could be pooled, they found no statistically significant difference in complications between ePTFE and collagen (relative risk 1.01)1. The question therefore cannot be answered with certainty.

Conflicts of interest. Puredent distributes both resorbable and non-resorbable membranes, including permamem and Jason from botiss. In the permamem study, the membrane, bone substitute material, and part of the fixation material were from botiss; two of the authors, Molnar and Windisch, are regular lecturers for the company, and the authors thank botiss for support with the surgical and postoperative management of the materials. According to the authors, the study did not receive funding from the company.4 In the analysis from Zurich, another manufacturer provided bone substitute material and membranes, and the authors state no conflicts of interest.2

Sources

  1. Cousiño DS, Egido-Moreno S, Navarro BG, Mejía HO, Blanco-Carrión A, López-López J. Failures and complications associated with resorbable and non-resorbable membranes in guided bone regeneration: A systematic review and meta-analysis. Med Oral Patol Oral Cir Bucal. 2026;31(4):e511-e521. DOI
  2. Strauss FJ, Schneider D, Jung RE, Kraus R, Thoma DS, Naenni N. Hard and soft tissue contour changes following simultaneous guided bone regeneration at single peri-implant dehiscence defects using either resorbable or non-resorbable membranes: a 6-month secondary analysis of a randomized controlled trial. Clin Oral Investig. 2025;29(5):231. DOI
  3. Poli PP, Beretta M, Maiorana C, Souza FÁ, Bovio A, Manfredini M. Therapeutic Strategies in the Management of Nonresorbable Membrane and Titanium Mesh Exposures Following Alveolar Bone Augmentation: A Systematic Scoping Review. Int J Oral Maxillofac Implants. 2022;37(2):250-269. DOI
  4. Palkovics D, Bolya-Orosz F, Pinter C, Molnar B, Windisch P. Reconstruction of vertical alveolar ridge deficiencies utilizing a high-density polytetrafluoroethylene membrane /clinical impact of flap dehiscence on treatment outcomes: case series/. BMC Oral Health. 2022;22(1):490. DOI
  5. Lee SR, Jang TS, Seo CS, Choi IO, Lee WP. Hard Tissue Volume Stability Effect beyond the Bony Envelope of a Three-Dimensional Preformed Titanium Mesh with Two Different Collagen Barrier Membranes on Peri-Implant Dehiscence Defects in the Anterior Maxilla: A Randomized Clinical Trial. Materials (Basel). 2021;14(19):5618. DOI